Home> Products> Clamp Meters> Meters> Wireless TRMS Power Clamp Meter w/ 3-Phase Rotation Tests
Wireless TRMS Power Clamp Meter w/ 3-Phase Rotation Tests
DL599

The UEi DL599 is an award-winning wireless 600A True-RMS HVAC/R clamp meter now offering Power Factor and Watt measurements. This flagship solution can wirelessly connect to a free App for logging, graphing and emailing results and features a 600A clamp capable of AC/DC amps and frequency readings. Each meter includes a set of silicone test leads, 2 K-Type thermocouples, threaded back probes for testing molex connectors, threaded alligator clips for hands-free testing, and a zippered carrying pouch.

The DL599 is safety rated at CAT IV 600V / CAT III 1000V and offers full HVAC functionality including preventative motor testing. The motor diagnostics suite includes a 3-phase motor rotation test, unbalanced current/voltage tests to determine a motor’s load efficiency, Low Z (low impedance) to improve accuracy by reducing ghost voltages, and a Low Pass Filter to screen out unwanted higher frequencies from Variable Frequency Drives.

DL599 is backed by a 2-Year limited warranty.

Dual Display Yes
Backlight Yes
Temperature Differential Yes
Hold Yes
Min/Max Yes
Ranging Auto/Manual
Auto Power Off Yes
Display Count 6000
Low Battery Warning Yes
Worklight Yes
Temperature Inputs K-Type
DC Zero Yes
Wireless Output Yes
Free App Available Yes (iOS® and Android™ compatible)
Protective Boot/Overmolding Yes
Magnetic Mount Yes
Warranty 2-Year limited
Audible and Visual Alerts Yes
K-Type Input Yes
Probe/Lead Storage Yes
Digital Yes

TRMS Yes
Frequency (Hertz) - Jaw input 1999Hz
DC Current (Amps) - Jaw input 600ADC
AC Current (Amps) - Jaw input 600AAC
LRA Inrush Yes
Power Factor Yes
Active Power Yes
Reactive Power Yes
Apparent Power Yes
Phase Rotation Yes
Voltage/Current Unbalance Yes
DC Volts 1000VDC
AC Volts 1000VAC
Frequency (Hertz) - Test lead input 99.99kHz
Duty Cycle (%) 1.0 to 99.0%
Resistance (Ohms) 60MΩ
Diode Yes
Capacitance (Farads) 9999µF
Continuity Yes
DC Micro Current (Amps) - Test lead input 2000µADC
Temperature -328°F to 2462 °F (-200°C to 1350°C)
Low Z Yes
NCV Detection Yes

ETL Listed cETLus 610101-1: 2012
CAT Rating CATIV 600V/CATIII 1000V 600A
RoHS Yes
FCC/IC Compliant FCC
Drop Protection 6 ft

Manual (Eng) Yes
Test Leads Silicone ATL58
Back Probes ABP3
Alligator Clips AAC3
Batteries AAA (4)
Temperature Probe ATT29 (2)
Pouch/Case AC560

Video 1
Video 2
Video 3
Optional - Replacement Accessories
AC560
ATTPC4
ABP3
AJW1
ATL58
ATT29
AAC3
ATHA1
ATTPC3
AMH3
ATLCAP